Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 107
Filter
1.
Med. U.P.B ; 43(1): 113-117, ene.-jun. 2024. tab
Article in Spanish | LILACS, COLNAL | ID: biblio-1531528

ABSTRACT

La reacción a medicamentos con eosinofilia y síntomas sistémicos denominada DRESS(por sus siglas en inglés, Drug Reaction with Eosinophilia and Systemic Symptoms) hace parte de un amplio espectro denominado toxicodermias. La incidencia exacta no es conocida en niños; sin embargo, en la literatura se ha estimado una tasa de mortalidad que puede llegar a ser tan alta como el 10 %. Presentamos el caso de una paciente adolescente con antecedente personal de trastorno afectivo bipolar (TAB), quien recibía de forma ambulatoria sertralina, quetiapina y trazodona. Por presencia de alucinaciones se adicionó litio al manejo. Diez días después acude al servicio de urgencias por aparición de erupción cutánea y síntomas sistémicos, por lo que se sospechó un cuadro clínico secundario a hipersensibilidad a los medicamentos.


The reaction to drugs with eosinophilia and systemic symptoms called DRESS (Drug Reaction with Eosinophilia and Systemic Symptoms) is part of a broad spectrum called toxicodermias. The exact incidence is not known in children; However, a mortality rate that can be as high as 10% has been estimated in the literature. We present the case of a teenage patient with a personal history of bipolar affective disorder (BD), who received sertraline, quetiapine and trazodone on an outpatient basis. Due to the presence of hallucinations, lithium was added to the management. Ten days later she went to the emergency department due to the appearance of a skin rash and systemic symptoms, for which a clinical condition secondary to hypersensitivity to medications was suspected.


A reação a medicamentos com eosinofilia e sintomas sistêmicos denominada DRESS (Por suas siglas em inglês Drug Reaction with Eosinophilia and Systemic Symptoms) faz parte de um amplo espectro denominado toxicodermias. A incidência exata não é conhecida em crianças; No entanto, uma taxa de mortalidade que pode chegar a 10% foi estimada na literatura. Apresentamos o caso de um paciente adolescente com história pessoal de transtorno afetivo bipolar (TAB), que recebeu sertralina, quetiapina e trazodona em regime ambulatorial. Devido à presença de alucinações, foi adicionado lítio ao manejo. Dez dias depois, recorreu ao pronto-socorro devido ao aparecimento de erupção cutânea e sintomas sistêmicos, suspeitando-se de quadro clínico secundário a hipersensibilidade a medicamentos.


Subject(s)
Humans , Adolescent
2.
Rev. estomatol. Hered ; 33(1): 76-82, ene. 2023. ilus
Article in Spanish | LILACS, LIPECS | ID: biblio-1441870

ABSTRACT

Mediante este caso se describen los criterios de selección del color en restauraciones indirectas con disilicato de litio en el sector anterior. Mujer de 34 años, atendida en la Facultad de Odontología de la Universidad Nacional de Concepción (FOUNC), Paraguay, por una preocupación estética del sector anterior, en especial la diferencia de color de las piezas dentarias. La rehabilitación consistió en la confección de coronas de disilicato de litio de las piezas 11, 12, 13, 14, 21, 22, 24, 25 y laminado para carillas de la pieza 23. Fueron aplicadas técnicas de selección de color individualizadas, pruebas de color y cementación antes del cementado final para obtener resultados altamente estéticos. Gracias a los resultados fue posible observar la conjunción de factores como la correcta selección del color del sustrato dentario, el cemento resinoso, el material de restauración y la comunicación eficiente con el laboratorio, fundamental para el éxito del tratamiento.


This case describes the color selection criteria for indirect lithium disilicate restorations in the anterior sector. A 34-year-old woman treated at the Faculty of Dentistry of the National University of Concepción (FOUNC), Paraguay, due to an aesthetic concern in the anterior sector, especially the difference in color of the teeth. The rehabilitation consisted of making lithium disilicate crowns for teeth 11, 12, 13, 14, 21, 22, 24, 25 and laminate for veneers for tooth 23. Individualized color selection techniques, color and cementation prior to final cementation for highly esthetic results. Thanks to the results, it was possible to observe the conjunction of factors such as the correct selection of the color of the dental substrate, the resinous cement, the restorative material, and efficient communication with the laboratory, essential for the success of the treatment.


Subject(s)
Humans , Female , Adult , Rehabilitation , Tooth , Dental Veneers , Dentistry
3.
Braz. dent. sci ; 26(4): 1-8, 2023. ilus, tab
Article in English | BBO, LILACS | ID: biblio-1512140

ABSTRACT

Objective: To evaluate the biaxial flexural strength (BFS) of lithium disilicate (L), cemented on different substrates (epoxy resin - E and metal - M) with dual-cure resin cement (Rc) and zinc phosphate cement (Zc), not aged, thermally aged (TC) or thermo-mechanical aged (TC/MC). Material and Methods: Disks of L, E, and M were fabricated, and the cementation was performed according to the following groups: ERc (L+E+Rc); MRc (L+M+Rc); MZc (L+M+Zc); EZc (L+E+Zc). Ten samples from each described group were tested in BFS, ten more samples were subjected to TC (1×104 cycles between 5 ºC and 55 ºC water), and the last 10 samples were subjected to TC/MC (MC: 1.2×106 cycles, 50 N, 3.8 Hz). The BFS test was performed and scanning electron microscopy (SEM) was performed to evaluate the failure mode. The effect of the cementation strategy (cement/substrate) was compared in each aging method and the effect of the aging method was evaluated for each cementation strategy by one-way ANOVA and Tukey post-hoc test (α=0.05). Results: The strength values were highest to M (237.8 ~ 463.9 MPa), in comparison to the E (41.03 ~ 66.76 MPa), despite aging and luting agent. Flexural strength data decreased after TC and TC/MC in groups cemented with Zc, but was stable when cemented with Rc. SEM analysis indicated that failure origins were located at the tensile surface of the L. Conclusion: Lithium disilicate discs cemented to the metallic substrate presented the highest biaxial flexural strength. The cementation with dual-cure resin cement did not decrease BFS after aging (AU)


Objetivo: Avaliar a resistência à flexão biaxial (BFS) do dissilicato de lítio (L), cimentado sobre diferentes substratos (resina epóxi - E e metal - M) com cimento resinoso dual (Rc) e cimento de fosfato de zinco (Zc), não envelhecido, submetido ao envelhecido térmico (TC) ou ao envelhecido térmico-mecânico (TC/MC). Material e Métodos: Foram confeccionados discos de L, E e M, e a cimentação foi realizada de acordo com os seguintes grupos: ERc (L+E+Rc); MRc (L+M+Rc); MZc (L+M+Zc); EZc (L+E+Zc). Dez amostras de cada grupo descrito foram testadas em BFS, mais dez amostras foram submetidas à TC (1×104 ciclos de imersão em água entre 5 ºC e 55 ºC), e as últimas 10 amostras foram submetidas à TC/MC (MC: 1.2 ×106 ciclos, 50 N, 3.8 Hz). Foram realizados os testes de BFS e a microscopia eletrônica de varredura (MEV) para avaliar o modo de falha. O efeito da estratégia de cimentação (cimento/substrato) foi comparado em cada método de envelhecimento e o efeito do método de envelhecimento foi avaliado para cada estratégia de cimentação por ANOVA a um fator e teste post-hoc de Tukey (α=0,05). Resultados: Os valores de resistência foram maiores para M (237.8 ~ 463.9 MPa), em comparação com E (41.03 ~ 66.76 MPa), independentemente do envelhecimento e do agente cimentante utilizado. Os dados de resistência à flexão diminuíram após TC e TC/MC nos grupos cimentados com Zc, mas se mantiveram estáveis quando cimentados com Rc. A análise MEV indicou que a origem das falhas estava localizada na superfície de tração do L. Conclusão: Os discos de dissilicato de lítio cimentados ao substrato metálico apresentaram maior resistência à flexão biaxial. A cimentação com cimento resinoso dual não diminuiu o BFS após o envelhecimento (AU)


Subject(s)
Aging , Cementation , Flexural Strength
4.
Braz. dent. sci ; 26(2): 1-11, 2023. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1425563

ABSTRACT

Objective: The present study aims to evaluate the color stability and degree of conversion of amine-free dual cured resin cement compared to light cured and amine-containing dual cured resin cements used with two different translucencies of thin esthetic restorations. Material and Methods: A total of 120 specimens were prepared for color stability testing (n=60). The specimens were divided into three main groups according to the resin cement type. Group 1: amine-free dual cured, Group 2: light cured, Group 3: amine-containing dual cured. Each group was further subdivided according to the ceramic translucency into two subgroups: high and low translucency. Color stability was assessed by a spectrophotometer before and after thermal aging. For the degree of conversion assessment (n=60), Fourier transform infrared spectroscopy was used at three different time intervals. Statistical analysis was performed using multi-factorial ANOVA, followed by one-way ANOVA with Bonferroni correction. Results: Amine-containing resin cement showed significantly higher ΔEab and ΔE00in both translucencies (4.5±0.3, 3.5±0.3 respectively for high translucency ceramic and 3.8±0.4, 3.0±0.3 respectively for low translucency) than the other tested cements (p<0.001). The highest degree of conversion (DC) was shown after 2 weeks by the amine-free dual cured resin cement (86.27±0.74). Conclusion: Amine-free dual cured resin cement can be an alternative to light cured one for cementation of thin veneers since it showed comparable color stability and high degree of conversion (AU)


Objetivo: O presente estudo tem como objetivo avaliar a estabilidade de cor e o grau de conversão do cimento resinoso dual sem amina em comparação com cimentos resinosos fotopolimerizáveis contendo amina usados com duas translucidezes diferentes em restaurações estéticas definitivas. Material e Métodos: Um total de 120 espécimes foram preparados para teste de estabilidade de cor (n=60). Os espécimes foram divididos em três grupos principais de acordo com o tipo de cimento resinoso. Grupo 1: polimerização dupla sem amina, Grupo 2: fotopolimerização, Grupo 3: polimerização dupla contendo amina. Cada grupo foi ainda subdividido de acordo com a translucidez da cerâmica em dois subgrupos: alta e baixa translucidez. A estabilidade da cor foi avaliada por um espectrofotômetro antes e após o envelhecimento térmico. Para a avaliação do grau de conversão (n=60), a espectroscopia de infravermelho com transformada de Fourier foi usada em três intervalos de tempo diferentes. A análise estatística foi realizada usando ANOVA multifatorial, seguida de ANOVA um faot com correção de Bonferroni. Resultados: O cimento resinoso contendo amina apresentou ΔEab e ΔE00 significativamente maiores em ambas as translucidezes (4,5±0,3, 3,5±0,3 respectivamente para cerâmica de alta translucidez e 3,8±0,4, 3,0±0,3 respectivamente para baixa translucidez) do que os outros cimentos testados (p< 0,001). O maior grau de conversão (DC) foi mostrado após 2 semanas pelo cimento resinoso dual sem amina (86,27±0,74). Conclusão: O cimento resinoso dual sem amina pode ser uma alternativa ao cimento polimerizável na restauração de facetas finas, uma vez que apresentou estabilidade de cor comparável e alto grau de conversão. (AU).


Subject(s)
Color , Resin Cements , Polymerization , Lithium
5.
Braz. dent. sci ; 26(1): 1-7, 2023. ilus
Article in English | LILACS, BBO | ID: biblio-1412847

ABSTRACT

Objective: the aim of this study was to compare the mechanical behavior of different ceramics when used in thin vertical preparations versus traditional horizontal preparation. Material and Methods: two stainless-steel dies were milled to simulate a minimally invasive vertical preparation (VP) and a traditional horizontal preparation (HP) for an all-ceramic crown of a maxillary first premolar. The stainless-steel dies were duplicated using epoxy resin. Eighty monolithic crowns were milled and divided into 2 groups according to preparation design. Each design group was subdivided into 4 sub-groups according to material (n=10): IPS e.max CAD (lithium disilicate), Bruxzir shaded zirconia (full contour zirconia), CeraSmart (resin nanoceramic) and CEREC Tessera (advanced lithium disilicate). The crowns were cemented on their relevant epoxy resin dies using self-adhesive resin cement. All specimens were subjected to 15,000 thermocycles and then loaded to fracture in a universal testing machine. Data were analyzed using two-way ANOVA and Tukey pair wise comparison test. Results: the fracture resistance mean values of the VP (1344 + 118 N) was significantly lower than the HP design (1646 + 191 N). Ceramic crowns made of full contour zirconia had higher fracture resistance mean values (2842 + 380 N) than advanced lithium disilicate (1272 + 125 N) followed by lithium disilicate crowns (983 + 52 N) and resin nanoceramic (882 + 61 N). Conclusion: both vertical and horizontal preparations, regardless the different ceramic materials, showed clinically acceptable fracture resistance values. (AU)


Objetivo: o objetivo deste estudo foi comparar o comportamento mecânico de diferentes cerâmicas quando utilizadas em preparos verticais finos ou preparos horizontais tradicionais. Material e Métodos: dois modelos de aço inoxidável foram fresados para simular um preparo vertical minimamente invasivo (PV) e um preparo horizontal tradicional (PH) para uma coroa totalmente em cerâmica de um primeiro pré-molar superior. As matrizes de aço inoxidável foram duplicadas usando resina epóxi. Oitenta coroas monolíticas foram fresadas e divididas em 2 grupos de acordo com o desenho do preparo. Cada grupo foi subdividido em 4 subgrupos de acordo com o material (n=10): IPS e.max CAD (dissilicato de lítio), zircônia Bruxzir (zircônia de contorno total), CeraSmart (resina nanocerâmica) e CEREC Tessera (dissilicato de lítio avançado). As coroas foram cimentadas em suas respectivas matrizes de resina epóxi usando cimento resinoso autoadesivo. Todos os espécimes foram submetidos a 15.000 ciclos térmicos e então carregados até a fratura em uma máquina de teste universal. Os dados foram analisados usando ANOVA com dois fatores e teste de comparação por pares de Tukey. Resultados: os valores médios de resistência à fratura do PV (1344 + 118 N) foram significativamente menores do que PH (1646 + 191 N). As coroas de cerâmica feitas de zircônia de contorno total apresentaram maiores valores médios de resistência à fratura (2842 + 380 N) do que dissilicato de lítio avançado (1272 + 125 N), seguido por coroas de dissilicato de lítio (983 + 52 N) e resina nanocerâmica (882 + 61 N). Conclusão: preparos verticais e horizontais, independentemente dos diferentes materiais cerâmicos, apresentaram valores de resistência à fratura clinicamente aceitáveis. (AU)


Subject(s)
Bicuspid , Dental Prosthesis , Tooth Crown , Resin Cements , Epoxy Resins , Fractures, Bone
6.
Odovtos (En línea) ; 24(3)dic. 2022.
Article in English | LILACS, SaludCR | ID: biblio-1406149

ABSTRACT

Abstract To evaluate stress distribution when applying vertical and tangential forces to 1mm thick occlusal veneers with different finish lines preparations, using the finite element method. One extracted third molar was prepared for occlusal veneers, firstly without any bevel. It was scanned in order to design two groups of lithium disilicate (G1A, G2A) and composite resin (G1B, G2B) occlusal veneers. Then, the third molar preparation was modified, beveling the finish line and it was subsequently scanned again to design the occlusal veneer groups with bevel (LD: G3A, G4A and CR: G3B, G4B). The four groups were subjected to different forces (400 N vertical and 900 N tangential). At 400 N, the non-beveled veneers showed slightly higher Von Mises stress values (G1A: 783 MPa and G1B 736.5 MPa) than the beveled veneers (G3A: 685.7 MPa and G3B: 675.8 MPa). However, when 900 N tangential forces were applied, the beveled occlusal veneers showed higher Von Mises stress values (G4A: 4297 MPa and G4B: 4133 MPa) than the non-beveled occlusal veneers (G2A: 2581.1 MPa and G2B: 3519.1 MPa). Furthermore, it was observed that the tissue under the occlusal veneers with bevel showed higher Von Mises stress values than the models without any bevel. Beveled and non-beveled occlusal veneers of lithium disilicate and composite resin presented similar stress distribution values when vertical forces of 400 N were applied; whereas with tangential forces of 900 N applied near to the finish line, the beveled groups presented notably higher stress values than the non-beveled groups. However, both finish line preparations presented adequate values for possible clinical performance.


Resumen Evaluar la distribución de estrés al aplicar fuerzas verticales y tangenciales en carillas oclusales de 1mm de espesor con diferentes líneas de terminación marginal por el método de elementos finitos. Se preparó un tercer molar extraído para carilla oclusal, primero sin bisel. Se escaneó para diseñar dos grupos de carillas oclusales de disilicato de litio (G1A, G2A) y resina compuesta (G1B, G2B). Después, esta preparación molar fue modificada, biselando la línea de terminación y escaneándola nuevamente para diseñar los grupos de carillas oclusales con bisel (DL: G3A, G4A and RC: G3B, G4B). Los 4 grupos fueron sometidos a fuerzas diferentes (400 N vertical y 900 N tangencial). Con 400 N, las carillas sin bisel presentaron ligera mayor tensión de Von Mises (G1A: 783 MPa y G1B 736.5 MPa) que las carillas con bisel (G3A: 685.7 MPa y G3B: 675.8 MPa). De distinta forma, al aplicar fuerzas tangenciales de 900 N, las carillas oclusales con bisel presentaron mayor tensión de Von Mises (G4A: 4297 MPa y G4B: 4133 MPa) que las carillas oclusales sin bisel (G2A: 2581.1 MPa y G2B: 3519.1 MPa). Además, se observó que los tejidos subyacentes a las carillas oclusales con bisel, presentaron mayor tensión de Von Mises, frente a los modelos sin bisel. Las carillas oclusales con y sin bisel de disilicato de litio y resina compuesta presentaron una distribución de estrés similar con fuerzas verticales de 400 N, por otro lado, con fuerzas tangenciales de 900 N, los grupos con bisel presentaron notablemente mayor tensión que los grupos sin bisel. Sin embargo, ambos diseños de terminación marginal presentaron valores adecuados para un posible desempeño clínico.


Subject(s)
Humans , Bite Force , Composite Resins , Dental Veneers
7.
Rev. colomb. ciencias quim. farm ; 51(2)mayo-ago. 2022.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1535839

ABSTRACT

Introducción: El trastorno bipolar TB es una enfermedad crónica y recurrente, según el DSM 5 se clasifica en los subtipos: trastorno bipolar I, trastorno bipolar II, ciclotimia y categorías residuales de formas atípicas que no encajan en los subtipos antes mencionados. La prevalencia del TB tipo I es similar entre hombres y mujeres, mientras que el TB tipo II ocurre con mayor frecuencia en mujeres. Según la Encuesta nacional de salud mental la prevalencia estimada del trastorno bipolar tipo I en Colombia es del 1,9% en los hombres y del 0,6% en las mujeres, para un porcentaje total de 1,3%. La etiología de TB incluye factores genéticos, neuro bioquímicos, neuro anatómicos, así como médicos y ambientales. El tratamiento del trastorno bipolar se puede dividir en dos fases distintas: manejo de un episodio inicial y tratamiento a largo plazo para prevenir recaídas, los fármacos utilizados comúnmente son: litio, antipsicóticos y anticonvulsivantes. Los estabilizadores del estado del ánimo aceptados por la FDA son: litio, carbamazepina, divalproato, y lamotrigina. Una reacción adversa a medicamentos (RAM) se define como cualquier respuesta nociva y no intencionada a un medicamento, constituye una importante causa de morbimortalidad y de aumento de los costes sanitarios. Los sistemas de farmaco-vigilancia permiten la identificación y prevención de los riesgos asociados al uso de medicamentos. Metodología: Se realizó una búsqueda bibliográfica mediante la base de datos PubMed, utilizando términos MeSH. Los criterios de inclusión utilizados fueron: a) Artículos publicados entre el año 2016 y 2021, b) Idioma inglés o español, c) Población a estudio: pacientes con diagnóstico de trastorno bipolar según criterios del DSM. Resultados: Se encontró que los efectos adversos severos de los estabilizadores del estado del ánimo como la carbamazepina y el ácido valproico son variados, se pueden presentar manifestaciones cutáneas como el síndrome de Stevens-Johnson, necrólisis epidérmica tóxica; manifestaciones hematológicas como anemia aplásica y manifestaciones hepáticas como lo son la hepatotoxicidad e hiperamonemia.


SUMMARY Introduction: Bipolar disorder TB is a chronic and recurrent disease, according to DSM 5 it is classified into subtypes: bipolar I disorder, bipolar II disorder, cyclothymia and residual categories of atypical forms that do not fit into aforementioned subtypes. Prevalence of type I TB is similar between men and women, while type II TB occurs more frequently in women. According to the National Mental Health Survey, estimated prevalence of type I bipolar disorder in Colombia is 1.9% in men and 0.6% in women, for a total percentage of 1.3%. Etiology of TB includes genetic, neuro biochemical, neuro anatomical, as well as medical and environmental factors. Treatment of bipolar disorder can be divided into two phases: management of an initial episode and long-term treatment to prevent relapses, drugs normally used are: Lithium, antipsychotics and anticonvulsants. Mood stabilizers accepted by FDA are: Lithium, carbamazepine, divalproex, and lamotrigine. An adverse drug reaction (ADR) is defined as any harmful and unintended response to a drug, it constitutes a major cause of morbidity and mortality and increased healthcare costs. Pharma-covigilance systems allow identification and prevention of risks associated with use of drugs. Methodology: A graphic search was performed using PubMed database, using MeSH terms. Inclusion criteria used were: a) Articles published between 2016 and 2021, b) English or Spanish language, c) Study population: Patients with a diagnosis of Bipolar Disorder according to DSM criteria. Results: It was found that severe adverse effects of mood stabilizers such as carbamazepine and valproic acid are varied, skin manifestations such as Stevens-Johnson's syndrome, toxic epidermal necrolysis can occur; Hematological manifestations such as aplastic anemia and hepatic manifestations such as hepatotoxicity and hyperammonemia.


Introdução: O transtorno bipolar TB é uma doença crônica e recorrente, segundo o DSM 5 é classificada em subtipos: transtorno bipolar I, transtorno bipolar II, ciclo-timia e categorias residuais de formas atípicas que não se enquadram nos subtipos mencionados. A prevalência de TB tipo I é semelhante entre homens e mulheres, enquanto a TB tipo II ocorre com mais frequência em mulheres. De acordo com a Pesquisa Nacional de Saúde Mental, a prevalência estimada de transtorno bipolar tipo I na Colômbia é de 1,9% nos homens e 0,6% nas mulheres, para um percentual total de 1,3%. A etiologia da TB inclui fatores genéticos, neuro-bioquímicos, neuro-anatômicos, médicos e ambientais. O tratamento do transtorno bipolar pode ser dividido em duas fases distintas: manejo de um episódio inicial e tratamento de longo prazo para prevenção de recidivas, os medicamentos comumente utilizados são: lítio, antipsicóticos e anticonvulsivantes. Os estabilizadores de humor aceitos pela FDA são: lítio, carbamazepina, divalproex e lamotrigina. Uma reação adversa a medicamento (ADR) é definida como qualquer resposta prejudicial e não intencional a um medicamento, é uma das principais causas de morbidade e mortalidade e aumento dos custos de saúde. Os sistemas de farmacovigilância permitem a identificação e prevenção dos riscos associados ao uso de medicamentos. Metodologia: Foi realizada pesquisa bibliográfica na base de dados PubMed, utilizando termos MeSH. Os critérios de inclusão utilizados foram: a) Artigos publicados entre 2016 e 2021, b) Língua inglesa ou espanhola, c) População do estudo: Pacientes com diagnóstico de Bipolar Desordem de acordo com os critérios do DSM. Resultados: Verificou-se que os efeitos adversos graves dos estabilizadores do humor como a carbamazepina e o ácido valpróico são variados, podendo ocorrer manifestações cutâneas como a síndrome de Stevens-Johnson, podendo ocorrer necrólise epidérmica tóxica; Manifestações hematológicas como anemia aplástica e manifestações hepáticas como hepatotoxicidade e hiperamonemia.

8.
Dement. neuropsychol ; 16(2): 249-252, Apr.-June 2022. graf, il. color
Article in English | LILACS | ID: biblio-1384675

ABSTRACT

ABSTRACT. Rapidly progressive dementia (RPD) is a rare neurological disorder. Drug toxicity is among the differential diagnoses, including the use of lithium, in which an overdosage might cause cognitive dysfunction. Clinical suspicion, laboratory confirmation, and drug interruption are key points in the management of lithium intoxication. We described a 66-year-old female patient under treatment with lithium who developed an RPD associated with parkinsonian symptoms. 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) showed an "Alzheimer-like" pattern, while cerebrospinal fluid biomarkers for the disease were negative. There was a significant clinical and radiological improvement after lithium interruption. Lithium intoxication is a potentially reversible cause of RPD, as demonstrated in this case report. Drug discontinuation should be considered even in patients with normal levels of this metal, if cognitive impairment is detected. 18F-FDG PET/CT images may show an "Alzheimer-like" image pattern in acute intoxication and are useful for monitoring these patients.


RESUMO. Demência rapidamente progressiva é uma condição rara, cujos diagnósticos diferenciais incluem intoxicação por drogas como lítio, podendo causar importante disfunção cognitiva. A suspeita clínica, a confirmação laboratorial e a interrupção do uso medicamentoso são elementos fundamentais em seu diagnóstico e manejo. Trata-se de paciente feminina, de 66 anos de idade, que apresentou quadro demencial após intoxicação por lítio. Tal quadro foi acompanhado de sintomas parkinsonianos, além de Tomografia por Emissão de Pósitrons com 18F-Fluodeoxiglicose (18F-FDG PET/CT) compatível com padrão "Alzheimer-like". Houve melhora objetiva de parâmetros clínicos e imaginológicos após a interrupção do uso medicamentoso. A intoxicação por lítio é uma causa potencialmente reversível de demência rapidamente progressiva. A descontinuação da droga deve ser considerada também em pacientes com níveis normais do metal no sangue se alterações cognitivas forem encontradas. Imagens 18F-FDG PET/CT podem demonstrar achados sugestivos de doença de Alzheimer na intoxicação aguda e parecem ser um método útil no seguimento.


Subject(s)
Humans , Female , Aged , Poisoning , Dementia , Lithium
9.
Rev. colomb. psiquiatr ; 51(2): 133-145, abr.-jun. 2022. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1394983

ABSTRACT

RESUMEN Introducción: El tratamiento del trastorno afectivo bipolar (TAB) con litio se ha relacionado con menos deterioro cognitivo y menores cambios en la anatomía estructural cerebral comparado con otros tratamientos. Sin embargo, los estudios son heterogéneos y son pocos los que evalúan si estos efectos están relacionados. El objetivo de este estudio es evaluar y relacionar el desempeno cognitivo y la neuroanatomía estructural en pacientes tratados con y sin litio. Métodos: Estudio de corte trasversal que incluyó a 48 sujetos con TAB I: 22 tratados con litio y 26 sin litio. Se evaluó el desempeno en las pruebas neuropsicológicas Wechsler III (WAIS III), TMTAyB (Trial Making Test), prueba de aprendizaje verbal de California (TAVEC), prueba de Figura compleja de Rey y prueba de clasificación de tarjetas de Wisconsin. Se evaluaron estructuras cerebrales obtenidas por resonancia magnétiva (RM) cerebral. Se calculó la diferencia de medias estandarizada (DME) entre ambos grupos, con ajuste por variables de confusión mediante puntuación de propensión, y se empleó el coeficiente de correlación de Spearman (p) para evaluar la relación existente entre el desempeno cognitivo y las regiones neuroanatómicas. Resultados: Respecto al grupo sin litio, el grupo con litio tuvo menos errores perseverativos en el Wisconsin (DME = -0,69) y mayores áreas corticales derecha e izquierda (DME = 0,85 y DME = 0,92); mayor superficie en el cíngulo anterior izquierdo (DME = 1,32), la corteza orbi-tofrontal medial derecha (DME = 1,17), el giro frontal superior derecho (DME = 0,82), los giros precentrales derecho e izquierdo (DME = 1,33 y DME = 0,98); mayor volumen de la amígdala derecha (DME = 0,57), el hipocampo derecho (DME = 0,66), el putamen derecho (DME = 0,87) y el tálamo derecho (DME = 0,67). En el grupo con litio, se encontró una correlación con dichos errores y el espesor del giro precentral izquierdo (p = -0,78), el volumen del tálamo derecho (p = -0,44) y la amígdala derecha (p = 0,6). Conclusiones: El grupo con litio tuvo mejor flexibilidad cognitiva y mayor dimensión en algunas regiones corticales frontales y subcorticales. Además, hubo correlación moderada a alta entre el desempeno en esta función ejecutiva y el espesor del giro precentral derecho, y los volúmenes del tálamo y la amígdala derecha. Estos hallazgos podrían indicar un efecto neuroprotector del litio


ABSTRACT Introduction: Lithium treatment of bipolar disorder (BD) has been associated with less impairment and fewer changes in structural brain anatomy compared to other treatments. However, the studies are heterogeneous and few assess whether these effects are related. The objective of this study was to evaluate and relate cognitive performance and structural neuroanatomy in patients treated with and without lithium. Methods: Cross-sectional study that included 48 subjects with BD-I, of which 22 were treated with lithium and 26 without lithium. Performance was assessed on Wechsler III (WAIS III), TMT A and B (Trial Making Test) neuropsychological tests, California verbal learning test (CVLT), Rey complex figure test and Wisconsin card sorting test. Brain structures obtained by magnetic resonance imaging (MRI) were evaluated. The standardised mean difference (SMD) between both groups was calculated, adjusted for confounding variables using a propen-sity score, and the Spearman correlation coefficient (p) was used to assess the relationship between cognitive performance and neuroanatomical regions. Results: Compared to the group without lithium, the group with lithium had fewer perse-verative errors in the Wisconsin test (SMD = -0.69) and greater left and right cortical areas (SMD = 0.85; SMD = 0.92); greater surface area in the left anterior cingulate (SMD = 1.32), right medial orbitofrontal cortex (SMD = 1.17), right superior frontal gyrus (SMD = 0.82), and right and left precentral gyrus (SMD = 1.33; SMD = 0.98); greater volume of the right amyg-dala (SMD = 0.57), right hippocampus (SMD = 0.66), right putamen (SMD = 0.87) and right thalamus (SMD=.67). In the lithium group, a correlation was found with these errors and the thickness of the left precentral gyrus (p = -0.78), the volume of the right thalamus (p =-0.44), and the right amygdala (p = 0.6). Conclusions: Thelithium group had better cognitive flexibility and greater dimension in some frontal and subcortical cortical regions. Furthermore, there was a moderate to high correlation between performance in this executive function and the thickness of the right precentral gyrus, and the volumes of the thalamus and the right amygdala. These findings could suggest a neuroprotective effect of lithium.

10.
Medicina (B.Aires) ; 82(1): 130-137, feb. 2022. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1365137

ABSTRACT

Abstract Lithium carbonate is a commonly prescribed drug for bipolar disorders. In addition to its action on the central nervous system, lithium has systemic effects on multiple organs such as kidney, heart, motor end plate, thyroid and parathyroid glands. It can cause hypothyroidism, hyperthyroidism, goiter and oph thalmopathy by different mechanisms. It increases intrathyroid iodine content or compete for iodine transport, resulting in low iodine uptake by the thyroid. It also inhibits the coupling of iodotyrosine residues to form iodothy ronines and inhibits the release of T4 and T3. Lithium has direct actions on parathyroid glands by antagonizing the calcium sensing receptor, which may induce hypercalcemia or even hyperparathyroidism, requiring surgery in some cases. Furthermore, it inhibits the expression of aquaporins, mainly aquaporin 2, in the renal collecting tubule by unknown mechanisms leading to nephrogenic diabetes insipidus. This adverse effect is usually reversible after drug withdrawal. However, some patients may present irreversible kidney damage due to chronic interstitial nephropathy.


Resumen El carbonato de litio es un fármaco que se prescribe comúnmente para el tratamiento de trastornos bipolares. Además de su acción sobre el sistema nervioso central, el litio tiene repercusiones sistémicas, afectando a múltiples órganos como el riñón, el corazón, la placa motora terminal y glándulas tiroides y paratiroides. Puede causar hipotiroidismo, hipertiroidismo, bocio y oftalmopatía por diferentes mecanismos; también aumentar el contenido de yodo intratiroideo o competir por el transporte de yodo, lo que resulta en una baja captación tiroidea de yodo. Inhibe el acoplamiento de residuos de yodotirosina para formar yodotironinas e inhibe la liberación de T4 y T3. Tiene acciones directas sobre las glándulas paratiroides antagonizando el receptor sensor de calcio, lo que puede inducir hipercalcemia e incluso hiperparatiroidismo, y puede requerir cirugía en algunos casos. Inhibe la expresión de acuaporinas en el túbulo colector renal, prin cipalmente acuaporina 2, por mecanismos que aún no se conocen, produciendo diabetes insípida nefrogénica; este efecto adverso suele ser reversible tras la suspensión del fármaco. Sin embargo, algunos pacientes pueden presentar daño renal irreversible por nefropatía intersticial crónica.

11.
Rev. med. (São Paulo) ; 101(2): e-193028, mar.-abr. 2022.
Article in English, Portuguese | LILACS-Express | LILACS | ID: biblio-1391496

ABSTRACT

Este estudo objetivou avaliar os potenciais efeitos adversos nos rins associado ao tratamento de longo prazo com lítio em pacientes com transtorno bipolar, a partir de uma revisão integrativa literatura. Os artigos foram identificados nas bases de dados SciELO, Medline (Pubmed) e Biblioteca Virtual em Saúde (BVS), publicados entre 2010 e 2021. Aplicados os critérios de inclusão e exclusão, identificaram-se 18 artigos para a análise. Verificou-se que o tratamento com lítio durante um período prolongado está associado à redução da taxa de filtração glomerular, porém, outras variáveis devem ser consideradas como idade e comorbidades associadas. Por outro lado, não foi associado evolução da doença renal crônica em estágio terminal por uso do medicamento. A investigação dos estudos revelou que a droga em doses terapêuticas e com monitoramento laboratorial contínuo não demonstrou toxicidade ou efeitos colaterais severos nos rins sendo a sua descontinuação relacionada com exarcebações do humor. [au]


This study aimed to assess the potential adverse effects on the kidneys associated with long-term lithium treatment in patients with bipolar disorder, based on an integrative literature review. The articles were identified in the SciELO, Medline (Pubmed) and Virtual Health Library (VHL) databases, published between 2010 and 2021. After applying the inclusion and exclusion criteria, 18 articles were identified for analysis. It was found that treatment with lithium for a prolonged period is associated with a reduction in the glomerular filtration rate, however, other variables must be considered, such as age and associated comorbidities. On the other hand, evolution of end-stage chronic kidney disease due to drug use was not associated. The investigation of the studies revealed that the drug at therapeutic doses and with continuous laboratory monitoring did not show toxicity or severe side effects in the kidneys and its discontinuation was related to mood exacerbations. [au]

12.
Prensa méd. argent ; 107(8): 397-404, 20210000. tab, fig
Article in Spanish | LILACS, BINACIS | ID: biblio-1358646

ABSTRACT

El suicidio en adolescentes representa una problemática de salud de suma importancia en la sociedad. El presente trabajo analiza los factores de riesgo asociados a la conducta suicida, sus correlaciones fisiopatológicas y su tratamiento con carbonato de litio. Los factores de riesgo asociados incluyen: el estrés, las crisis vitales propias de la población de estudio, y factores externos como el uso de pantallas y consumo de medios de comunicación. A su vez, las patologías psiquiátricas de base, en especial el trastorno depresivo mayor, se relacionan de manera positiva con conductas suicidas en adolescentes. Las conductas suicidas estarían vinculadas con cambios morfológicos y moleculares en el sistema nervioso. Los estados proinflamatorios mediados principalmente por la enzima glucógeno sintasa quinasa 3 beta (GSK3 ), se observarían con mayor frecuencia en sujetos con conductas suicidas. A su vez, la disminución de la expresión del factor neurotrófico derivado del cerebro (BDNF) a nivel central predispondría a mayor incidencia de suicidio. La alteración del tono serotoninérgico central sería otro factor de riesgo de suicidio en adolescentes. Las alteraciones serotoninérgicas se vincularían con conductas suicidas de tipo violentas, agresivas e impulsivas, con alta prevalencia en población adolescente. El presente trabajo muestra que el efecto anti-suicida del litio estaría mediado por la inhibición de la GSK3 , como así también por el aumento del tono serotoninérgico. De esta forma el litio disminuiría el estado proinflamatorio central, generaría un aumento de BDNF (con incremento de la supervivencia neuronal), con la subsecuente modulación de la respuesta serotoninérgica. Dada la alta prevalencia de suicidio en dicha población, es necesario contar con opciones terapéuticas eficaces y seguras, respaldados por ensayos clínicos que respalden su uso.


Suicide in adolescents represents a critical health problem in society. The present work analyzes the risk factors associated with suicidal behavior, their pathophysiological correlations, and their treatment with lithium carbonate. Associated risk factors include stress, vital crises typical of the study population, and external factors such as the use of screens and consumption of communication media. In turn, primary psychiatric pathologies, especially major depressive disorder, are positively related to suicidal behaviors in adolescents. Suicidal behaviors would be linked to morphological and molecular changes in the nervous system. Pro-inflammatory states mediated mainly by the enzyme glycogen synthase kinase 3 beta (GSK3 ) would be observed more frequently in subjects with suicidal behaviors. In turn, decreased expression of brain-derived neurotrophic factor (BDNF) at the central level would predispose to a higher incidence of suicide. The alteration of the central serotonergic tone would be another risk factor for suicide in adolescents. Serotonergic alterations would be associated with violent, aggressive and impulsive suicidal behaviors, with a high prevalence in the adolescent population.The anti-suicidal effect of lithium might be mediated by the inhibition of GSK3 , as well as the increase in serotonergic tone. In this way, lithium might decrease the central pro-inflammatory state, generate an increase in BDNF (with increased neuronal survival), and subsequently modify the serotonergic response. Given the high prevalence of suicide in this population, it is necessary to have effective and safe therapeutic options supported by clinical trials that support their use.


Subject(s)
Humans , Adolescent , Suicide/prevention & control , Therapeutics/methods , Risk Factors , Lithium Compounds/therapeutic use , Suicidal Ideation
13.
Acta odontol. latinoam ; 34(2): 143-148, June 2021. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1339038

ABSTRACT

ABSTRACT The aim of this study was to evaluate the amount of radiating energy transmitted through lithium disilicate discs of different thicknesses and opacities with different curing units (CU). Discshaped specimens 8 mm in diameter and 1.5 mm or 0.7 mm thick were designed with Zbrush® and Cura 3D® software, milled from HT and MO IPS e-maxCAD blocks (Ivoclar Vivadent) with Ceramill Mikro 4 (Amann Girrbach, Austria) and processed according to manufacturer instructions. Thickness was checked with a Mitutoyo (México) caliper. Four groups (n=4) were formed: G1(HT/1.5 mm), G2(MO/1.5 mm), G3(HT/0.7 mm) y G4(MO/0.7 mm), and the effect of three CUs: Coltolux (Coltene- Whaledent), LED.C, (Woodpecker Medical Instrument Co.Ltd) and Deepcure L(3M-ESPE) was tested Measurements were taken with a halogen and LED radiometer (Woodpecker® LM-1-Guilin Woodpecker Medical Instrument Co.Ltd) after applying the guide of each CU directly on the reading window (d) and after interposing each of the specimens. The ratio of transmitted energy was determined in each case and data was analyzed with repeated measures ANOVA and Tukey test for multiple comparisons. LED.C: d:1600 mW/cm2, G1: 0.31(0.00), G2: 0.14(0.00) G3: 0.54(0.01), G4: 0.38(0.01); Deepcure L: d:1500 mW/cm2, G1: 0.34(0.01), G2: 0.20(0,00), G3: 0.56(0.01), G4: 0.41(0.02); Coltolux: d:1275 mW/cm2, G1: 0.44(0.01), G2: 0.24(0,00), G3: 0.65(0.01), G4: 0.47(0,00). Statistically significant differences were found among the curing units (P<0.001) and for the interaction CU-thickness (P<0.001) and CU-opacity (P=0.023). Within the conditions of this study, the ratio of light transmitted through lithium disilicate structures is related to their thickness and opacity, and to the curing unit employed.


RESUMEN Uno de los factores relacionados con éxito de las restauraciones y prótesis de cerámica de matriz vítrea es el logro de una fijación adhesiva para lo cual la correcta polimerización del medio de fijación es un requisito fundamental. El objetivo de este trabajo fue valorar la transmitancia de una cerámica a base de disilicato de litio de diferentes opacidades y espesores, con distintas unidades de curado. Probetas con forma de discos de 8mm de diámetro y dos diferentes espesores (1.5 mm y 0.7 mm) fueron diseñadas con Zbrush® y Cura 3D®, maquinadas a partir de bloques HT y MO de IPS e-maxCAD (Ivoclar Vivadent) con Ceramill Mikro 4 (Amann Girrbach, Austria) y procesadas según instrucciones del fabricante. Se obtuvieron cuatro grupos (n=4): G1(HT/1.5 mm), G2(MO/1.5 mm), G3(HT/0.7 mm) y G4(MO/0.7 mm),los espesores se controlaron con un calibre (Mitutoyo, México). A continuación, se registró la irradiancia con cada una de las unidades de curado (UC) Coltolux (Coltene- Whaledent) LED.C, (Woodpecker Medical Instrument Co.Ltd) y Deepcure L(3M-ESPE), aplicadas sobre la ventana de un radiómetro (Halogen and led radiometer Woodpecker® LM-1-Guilin Woodpecker Medical Instrument Co.Ltd) en forma directa (d), y luego de interponer los diferentes especímenes y se calculó la proporción de energía transmitida en cada caso. Los datos se analizaron con ANOVA de medidas repetidas y prueba de Tukey para las comparaciones múltiples. LED.C: d:1600 mw/ cm2, HT/0,7mm: 0,54(0,01), HT/1,5mm:0,31(0); MO/0,7mm: 0,38(0,01), MO/1,5mm: 0,14(0,00); Deepcure L: d:1500 mW/ cm2, HT/0,7 mm: 0,56(0,01), HT/1,5 mm: 0,34(0,01), MO/0,7 mm: 0,41(0,02), MO/1,5 mm: 0,20(0,00); Coltolux: d:1275 mw/ cm2, HT/0,7 mm:0,65 (0,01), HT/1,5 mm:0,44(0,01), MO/0,7 mm: 0,47(0,00), MO/1,5mm: 0,24(0,00). Se encontraron diferencias estadísticamente significativas entre las diferentes unidades de curado (P<0,001), y en la interacción unidades de curado-espesor (P<0,001) y unidades de curado-opacidad (P=0,023). La proporción de energía luminosa transmitida por una estructura de cerámica de disilicato de litio depende del espesor y opacidad de la restauración y de la unidad de curado utilizada.

14.
Braz. dent. sci ; 24(3): 1-9, 2021. tab, ilus, graf
Article in English | BBO, LILACS | ID: biblio-1281728

ABSTRACT

Objective: The present study aimed to evaluate the effect of repressing and different surface treatment protocols on the shear bond strength of lithium disilicate glass-ceramics. Material and Methods: A total of 52 lithium disilicate glass-ceramic discs (IPS emax Press, Ivoclar Vivadent) were fabricated using the heat-press technique. The discs were divided into two groups; group (P): discs fabricated from new e.max ingots (n=26), group (R): discs fabricated from reused e.max buttons (n=26). Each group was subdivided into subgroup (E): discs were etched with hydrofluoric acid (9.5%) (n=13), subgroup (S): discs were air-abraded with 110 µm alumina particles. All specimens were subjected to X-ray Diffraction analysis, Scanning Electron Microscope, Energy Dispersive X-Ray, Thermo-Cycling, and Shear Bond Strength Testing. Results: Repressed Etched subgroup (RE) recorded the statistically highest shear bond strength value, followed by the Pressed Etched subgroup (PE), while the statistically lowest shear bond strength value was recorded for the Pressed Air-Abraded subgroup (PS) and Repressed Air-Abraded subgroup (RS). Conclusion: Repressing the leftover buttons for the construction of new lithium disilicate glass-ceramic restorations has no adverse effect on the bond strength of the resin cement to the ceramic. Hydrofluoric acid surface treatment improves the shear bond strength and durability of resin cement bond to both pressed and repressed lithium disilicate glass-ceramic. Air-abrasion cannot be considered as a reliable surface treatment when bonding to lithium disilicate glass-ceramics. (AU)


Objetivo: O presente estudo teve como objetivo avaliar o efeito da reprensagem e de diferentes protocolos de tratamento de superfície na resistência ao cisalhamento de vitrocerâmica de dissilicato de lítio. Materiais e Métodos: Um total de 52 discos de vitrocerâmica de dissilicato de lítio (IPS emax Press, Ivoclar Vivadent) foram fabricadas usando a técnica de prensagem quente. Os discos foram divididos em dois grupos: grupo (P): discos fabricados a partir de novo lingotes de e-max (n=26), grupo (R): discos fabricados a partir de botões de emax reutilizados (n=26). Cada grupo foi subdividido em subgrupo (E): discos condicionados com ácido fluorídrico (9,5%) (n=13), subgrupo (S) discos foram abrasivos com partícula 110 µm de alumínio. Todos os espécimes foram submetidos a analise de difração de raio-x, microscópio eletrônico de varredura, raio-x de energia dispersiva, termociclagem e teste de resistência de cisalhamento. Resultados: O subgrupo Reprensado-condicionado (RE) registrou o valor estatisticamente mais alta em relação a resistência ao cisalhamento, seguido pelo subgrupo Prensado-condicionado (PE), enquanto o valor estatisticamente mais baixo de resistência ao cisalhamento foi o subgrupo Prensado-Jateado (OS) e o subgrupo Reprensado-Jateado (RS). Conclusão: A reprensagem dos botões restantes para a construção de novas restaurações vitrocarâmicas de dissilicato de lítio não apresentou efeitos adversos na resistência de unicãp do cimento resinoso à cerâmica. O tratamento de superfície com ácido fluorídrico melhora a resistência ao cisalhamento e a durabilidade do cimento resinoso para vitrocerâmica de dissilicato de lítio prensada e reprimida. A abrasão por ar não pode ser considerada um tratamento de superfície confiável quanto a colagem da vitrocerâmica de dissilicato de lítio (AU)


Subject(s)
X-Ray Diffraction , Resin Cements , Shear Strength , Microscopy, Electrochemical, Scanning
15.
Braz. dent. sci ; 24(3): 1-10, 2021. tab, ilus, graf
Article in English | BBO, LILACS | ID: biblio-1282057

ABSTRACT

Objective: The aim of this study was to analyze mechanical and thermal stresses of hybrid ceramic and lithium disilicate based ceramic of CAD/CAM inlays using 3D Finite element analysis. Material and Methods:A three dimensions finite element model of permanent maxillary premolar designed according to standard anatomy with class II cavity preparation for inlay restored with two different ceramic materials: 1- Hybrid ceramic (Vita Enamic), 2- Lithium disilicate based ceramic (IPS e.max CAD). Totally six runs were performed on the model as: One loading case for each restorative material was tested in stress analysis; seven points of loading with 140N vertically applied at palatal cusp tip and cusp slop, marginal ridges and central fossa while the models base was fixed as a boundary condition in the two cases. Two thermal analysis cases were performed for each restoration material by applying 5ºC and 55ºC on the crown surface including the restoration surface. Results:The results of all structures were separated from the rest of the model to analyze the magnitude of stress in each component. For each group, maximum stresses on restorative materials, cement, enamel, and dentin were evaluated separately. Both ceramic materials generated similar stress distribution patterns for all groups when a total occlusal load of 140 N was applied. Conclusion: Thermal fluctuations of temperature have a great influence on the stresses induced on both restoration and tooth structure. IPS e.max CAD produced more favorable stresses on the tooth structure than Vita Enamic. (AU)


Objetivo: O objetivo deste estudo foi analisar o estresse mecânico e térmico de inlays de cerâmica hibrida e a base de dissilicato de lítio através da análise em 3D de elementos finitos. Material e Métodos: Foi realizado o design de um modelo de três dimensões em elementos finitos de um pré-molar superior de acordo com os padrões anatômicos de um preparo de cavidade classe II para restauração de inlay em dois tipos de cerâmicas diferentes: 1 Cerâmica hibrida (Vita Enamic), 2 ­ Cerâmica a base de dissilicato de lítio (IPS e.max CAD). No total, seis execuções foram realizadas no modelo como: Uma carga para cada material restaurador foi testado para análise de tensão; sete pontos de carga com 140N foi aplicado verticalmente na ponta da cúspide palatina, saliência da cúspide, cristas marginais e fossa central enquanto a base do modelo foi fixada como uma condição de limite nos dois casos. Duas análises térmicas foram realizadas para cada material de restauração, aplicando 5ºC e 55ºC na superfície da coroa, incluindo a superfície da restauração. Resultados: Os resultados de todas as estruturas foram separados do resto do modelo para analisar a magnitude do estresse de cada componente. Para cada grupo, o máximo de estresse nos materiais restauradores, cemento, esmalte e dentina foram avaliados separadamente. Padrões similares de distribuição de estresse foram gerados em todos os grupos para ambos os materiais cerâmicos, quando a carga oclusal de 140 N foi aplicada. Conclusão: As variações térmicas de temperatura têm uma grande influência nas tensões induzidas na restauração e na estrutura dentária. IPS e.max CAD produziu tensões mais favoráveis na estrutura dentária do que o Vita Enamic (AU)


Subject(s)
Bicuspid , Finite Element Analysis , Dental Cavity Preparation , Dental Cementum , Dental Enamel , Dentin
16.
Braz. dent. sci ; 24(3): 1-9, 2021. tab, ilus, graf
Article in English | BBO, LILACS | ID: biblio-1282061

ABSTRACT

Objective: The recycling of heat pressed lithium disilicate glass-ceramic leftover material has been reported to be done by dental laboratories. The effect of this procedure on the fracture resistance of single crowns is unknown, especially when it is functioning inside the oral cavity with subsequent exposure to temperature changes and cycles of mastication. Material and Methods: A total of 28 lithium disilicate glass-ceramic crowns (IPS emax Press) were constructed and randomly assigned into two groups (n = 14); Group (P): Included crowns fabricated from new e.max ingots. Group (R): Included crowns fabricated from repressed e.max buttons. Specimens of each group were divided into two equal subgroups (n = 7) according to whether the aging of specimens will be performed or not before fracture resistance testing. Subgroup (N), samples were subjected to fracture resistance without thermo-mechanical aging, while subgroup (A), samples were subjected to thermo-cycling and cyclic loading before being subjected to fracture strength testing. Different methods; SEM, XRD, EDAX were used to characterize the properties of lithium disilicate glass-ceramics before and after repressing. Results: The highest statistically significant fracture resistance value was recorded for the subgroup (RN) repressed/non-aged, followed by the subgroup repressed/aged (RA), while the lowest statistically significant mean value was recorded for the subgroup pressed/aged (PA). There was no significant difference between pressed/non-aged (PN) and repressed/aged (RA) subgroups. Conclusion: Repressing of leftover buttons may increase the fracture resistance of IPS emax Press crowns. Thermo-mechanical aging may negatively affect the fracture resistance of IPS emax Press crowns, yet Repressing may decrease this effect. Clinical implications:This is a novel approach that targets a point of research that has not been investigated before. It elaborates how repressing may decrease the effect of aging and increase the fracture resistance of lithium disilicate crowns. Thus, recycling of lithium disilicate glass ceramics might decrease its failure and prolong their serviceability (AU)


Objetivo: A reutilização de material residual de vitrocerâmicas de dissilicato de lítio prensadas a quente tem sido realizada pelos laboratórios de prótese. O efeito deste procedimento na resistência à fratura de coroas unitárias é desconhecido, especialmente quando estão em função na cavidade oral com subsequente exposição às variações de temperatura e ciclos mastigatórios. Material e Métodos: Vinte e oito coroas de dissilicato de lítio (IPS e.max Press) foram confeccionadas e divididas aleatoriamente em dois grupos (n = 14); Grupo (P): Incluiu coroas fabricadas de pastilhas novas de e.max; Grupo (R): Incluiu coroas fabricadas de e.max reprensado. As amostras de cada grupo foram divididas em dois subgrupos iguais (n = 7) de acordo com a realização de envelhecimento dos espécimes antes do teste de resistência à fratura. As amostras do subgrupo (N) foram submetidas ao teste de resistência à fratura sem envelhecimento termomecânico, enquanto as amostras do subgrupo (A) foram submetidas ao envelhecimento termomecânico antes do teste de resistência à fratura. Diferentes métodos (MEV, DRX e EDS) foram usados para caracterizar as propriedades da cerâmica de dissilicato de lítio antes e depois da reprensagem. Resultados: O maior valor de resistência à fratura estatisticamente significativo foi do subgrupo (RN) reprensado/não envelhecido, seguido pelo subgrupo reprensado/envelhecido (RA), enquanto o menor valor médio estatisticamente significativo foi do subgrupo prensado/envelhecido (PA). Não houve diferença estatística entre os subgrupos prensado/não envelhecido (PN) e reprensado/envelhecido (RA). Conclusão: A reprensagem de material residual pode aumentar a resistência à fratura de coroas de IPS e.max Press. O envelhecimento termomecânico pode afetar negativamente na resistência à fratura deste material, enquanto a reprensagem pode diminuir este efeito. Relevância clínica: Esta é uma nova abordagem que busca estudar um tema que não havia sido investigado anteriormente. Este estudo demonstrou como a reprensagem pode diminuir o efeito do envelhecimento e aumentar a resistência à fratura de coroas de dissilicato de lítio. Assim, a reutilização de vitrocerâmicas de dissilicato de lítio pode diminuir o risco à falha e aumentar o tempo de vida útil (AU)


Subject(s)
Crowns , Recycling , Flexural Strength , Mouth
17.
Braz. dent. sci ; 24(1): 1-8, 2021. tab, ilus
Article in English | BBO, LILACS | ID: biblio-1145549

ABSTRACT

Objective: The aim of this study was to compare the bond strength of High-Translucency zirconia (HT) and lithium disilicate dental ceramics, under different surface treatments. Material And Methods: For this, ceramics were divided into groups: Control Group (C) (n = 5), lithium disilicate sheets, conditioned with 10% hydrofluoric acid, followed by application of 37% phosphoric acid, silane and universal adhesive application; Group HTAI (n = 5), HT zirconia sheets were blasted with silica oxide, followed by the application of universal adhesive; Group HTPAI (n = 5), HT zirconia sheets were blasted with silica oxide, followed by the application of non-thermal plasma and universal adhesive and the HTP Group (n = 5), HT zirconia received only the application of non-thermal argon plasma. Subsequently, the specimens of each group were subjected to a cementation process with resin cement, obtaining cylinders. After 24 h of storage, in distilled water, at 37°C, the specimens were subjected to a mechanical micro-shear test. The data obtained were submitted to ANOVA One-way followed by the Tukey test (5%). Results: The HTP Group was excluded from the statistical analysis, as adhesions failed within the storage period. In addition, it was not possible to verify a statistical difference between the control group C and the experimental groups HTAI and HTPAI. Conclusion: The results showed that the applicability of high translucency zirconia can potentially be compared to the lithium disilicate bond strength, when submitted to the same surface treatments, except for the plasma application, which alone was not effective (AU)


Objetivo: O objetivo deste estudo foi comparar a resistência adesiva das cerâmicas dentárias de zircônia de alta translucidez e dissilicato de lítio. Materiais e Métodos: Para isso, cerâmicas foram divididas em grupos: Grupo Controle (C) (n = 5), lâminas de dissilicato de lítio, condicionadas com ácido fluorídrico 10%, seguido de aplicação do ácido fosfórico 37%, aplicação de silano e aplicação do adesivo universal; Grupo HTAI (n = 5), lâminas de zircônia HT foram submetidas ao jateamento com óxido de sílica, seguido da aplicação do adesivo universal; Grupo HTPAI (n = 5), lâminas de zircônia HT foram submetidas ao jateamento com óxido de sílica, seguido da aplicação do plasma não térmico e do adesivo universal e o Grupo HTP (n = 5), lâminas de zircônia HT receberam apenas a aplicação do plasma não térmico de argônio. Posteriormente, os espécimes de cada grupo foram submetidos a um processo de cimentação com cimento resinoso, obtendo-se cilindros. Após 24h, de armazenamento em água destilada a 37°C, os espécimes foram submetidos a ensaio mecânico de microcisalhamento. Os dados obtidos foram submetidos à ANOVA 1-fator seguido pelo teste de Tukey (5%). Resultados: O Grupo HTP foi descartado da análise estatística, pois as adesões falharam dentro do período de armazenamento. Além disso, não foi possível verificar diferença estatística entre o grupo controle C e os experimentais HTAI e HTPAI. Conclusão: Os resultados mostraram que a aplicabilidade das zircônias de alta translucidez pode potencialmente ser comparada à resistência adesiva da cerâmica de dissilicato de lítio, quando submetidas aos mesmos tratamentos de superfície, com exceção da aplicação de plasma, que isoladamente não foi efetiva (AU)


Subject(s)
Metal Ceramic Alloys , Dentin-Bonding Agents , Resin Cements , Dental Cements
18.
Braz. dent. sci ; 24(2): 1-7, 2021. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1178409

ABSTRACT

Background: To present the benefits of high power lasers (Er: YAG and Nd: YAG) over the use of the high speed turbine for the extraction of ceramics restorations, without damaging the surfaces of the teeth; being a relatively easier and faster procedure without the use of anesthetic agents, and the preparation of the ceramic restorations and cementing in the single session; with a follow-up of 1 year. Objective: The benefits of lasers over high-speed turbine mechanical instrumentation for crown removal encompass efficient restoration recovery without damage to tooth surfaces; and a relatively easier and faster procedure without the use of anesthetic agents. Methods: The Er: YAG laser (no contact; 3.2-4.0 W, 20 Hz) was used to extract the porcelain prosthesis, followed by a gingivectomy with the Nd: YAG laser on tooth 12 to improve the gingival contour. The dental surfaces where the ceramic prosthesis will be cemented were scanned. Then, CAD / CAM technology was used to make the ceramic veneers that were cemented in the same session. Results: The efficacy the Er:YAG laser energy was observed by the decreased of the time to remove all-ceramic materials through ablation of bonding cements, reducing working time by 75% compared to a high-speed turbine. Conclusions: An Er: YAG laser can safely remove lithium disilicate crowns with the settings used in this study. Laser-assisted removal of all ceramic PDFs is a promising treatment protocol. The use of the Nd: YAG (2.0 W power, short 20Hz, 320 µm optical fiber, in contact) laser allowed gingivoplasty to be performed, automatically cauterizing avoiding post-operative bleeding, and facilitating the preparation of ceramic restorations the same day. The use of high-power lasers and the use of accompanying CAD / CAM technology allowed this clinical case to be completed in a single visit without the use of temporary restorations, achieving absolute patient satisfaction. (AU)


Antecedentes: Apresentar os benefícios dos lasers de alta potência (Er: YAG e Nd:YAG) sobre o uso da turbina de alta velocidade para a remoção de restaurações cerâmicas, sem danificar as superfícies dos dentes; sendo um procedimento relativamente mais fácil e rápido evitando o uso de agentes anestésicos, conseguindo fazer o preparo das restaurações de cerâmica e cimentação em uma única sessão; com seguimento de 1 ano. Objetivo: Os benefícios dos lasers sobre a instrumentação mecânica com turbina de alta velocidade para a remoção da coroa abrangem a recuperação eficiente da restauração sem danos às superfícies dos dentes; e um procedimento relativamente mais fácil e rápido sem o uso de agentes anestésicos. Métodos: O laser Er: YAG (sem contato; 3,2-4,0 W, 20 Hz) foi utilizado para remover a prótese de porcelana, seguido de gengivectomia com o laser Nd: YAG no dente 12 para melhorar o contorno gengival. As superfícies dentais onde a prótese de cerâmica será cimentada foram escaneadas. Em seguida, a tecnologia CAD / CAM foi utilizada para confeccionar as facetas de cerâmicas que foram cimentadas na mesma sessão. Resultados: A eficácia da energia do laser Er: YAG foi observada pela diminuição do tempo na remoção dos materiais cerâmicos por meio da ablação dos cimentos de ligação, reduzindo o tempo de trabalho em 75% em relação a uma turbina de alta velocidade. Conclusão: Um laser Er: YAG pode remover com segurança as coroas de dissilicato de lítio com as configurações usadas neste estudo. A remoção assistida por laser de todos os PDFs de cerâmica é um protocolo de tratamento promissor. O uso do laser Nd: YAG (2,0 W potência, curta 20Hz, 320 µm fibra ótica, em contato) permitiu a realização da gengivoplastia, cauterizando automaticamente evitando sangramento pós-operatório e facilitando o preparo das restaurações cerâmicas no mesmo dia. O uso de lasers de alta potência e o uso da tecnologia CAD / CAM que o acompanha permitiram que este caso clínico fosse concluído em uma única visita, sem o uso de restaurações temporárias, alcançando a satisfação absoluta do paciente (AU)


Subject(s)
Humans , Female , Middle Aged , Computer-Aided Design , Dental Materials , Lasers, Solid-State
19.
Braz. dent. sci ; 24(2): 1-9, 2021. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1177588

ABSTRACT

Objective: The purpose of the present study was to synthesize and characterize lithium disilicate glass-ceramics through the Li2O-SiO2system for determining the most satisfactory sintering parameter by evaluating the crystalline composition, microstructure and mechanical properties. Material and methods: The glass-ceramics were prepared from a glass precursor by means of the melting/cooling technique with a composition of 33.33 Li2O and 66.67 SiO2 (mol.%). The specimens were compressed by the uniaxial pressing technique and three different thermal treatments were used for sintering: 850 °C (Group 1), 900 °C (Group 2), and 950 °C (Group 3), which were determined based on the differential scanning calorimetry (DSC) result. The glass-ceramics were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), Archimedes method, microhardness and biaxial flexural strength analyses. Results: The results regarding XRD predominantly showed lithium disilicate phase for all the heat treatments performed. Moreover, grains with a needle form were more predominantly observed in the SEM images for Group 3, as well as a higher densification and consequently higher mechanical properties. In contrast, Group 1 presented the lowest mechanical properties and densification, as well as the highest porosity. Conclusion: The present study demonstrated how extremely important it is to follow the heat treatment recommended by the manufacturers of ceramics, including time and temperature, which possess direct effects in the crystalline phase formation, as well as in the material's microstructure and mechanical properties (AU)


Objetivo: O presente estudo teve como objetivo sintetizar e caracterizar uma vitrocerâmica de dissilicato de lítio através do sistema Li2O-SiO2para determinar o parâmetro de sinterização mais satisfatório através da avaliação da composição cristalina, microestrutura e propriedades mecânicas. Material e Métodos: As vitrocerâmicas foram preparadas a partir de um vidro precursor pelo método fusão/resfriamento utilizando a composição de 33.33 Li2O e 66.67 SiO2 (mol.%). As amostras foram prensadas utilizando uma técnica de prensagem uniaxial e três tratamentos térmicos diferentes foram utilizadas para sinterização: 850 °C (Grupo 1), 900 °C (Grupo 2), e 950 °C (Grupo 3), que foram determinados através do resultado da análise diferencial de calorimetria. As vitrocerâmicas foram caracterizadas através das análises de difração de raios X (DRX), microscopia eletrônica de varredura (MEV), métodos de Arquimedes, microdureza e ensaio de flexão biaxial. Resultados: Os resultados de DRX mostraram predominantemente a fase de dissilicato de lítio para todos os tratamentos realizados. Além disso, grãos com forma agulhada foram mais predominantemente observados por MEV no grupo 3, assim como uma densificação maior e consequentemente valores maiores das propriedades mecânicas. Em contraste, o grupo 1 apresentou os menores valores de propriedades mecânicas e densificação, e também a maior porosidade. Conclusão: O presente estudo demonstrou como é extremamente importante seguir o tratamento térmico recomendado pelos fabricantes de cerâmica, incluindo tempo e temperatura, que possuem efeitos diretos na formação da fase cristalina, assim como na microestrutura do material e propriedades mecânicas. (AU)


Subject(s)
X-Ray Diffraction , Microscopy, Electron, Scanning , Crystallization
20.
Braz. dent. sci ; 24(4, suppl 1): 1-12, 2021. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1352586

ABSTRACT

Objective: To evaluate the influence of background, substrates and thickness on the color and light behaviour of two ZLS glass ceramics. Material and Methods: Standardized disc-shape specimens (12 x 1.2 mm), color A1 HT, of Celtra Duo and Vita Suprinity (n=30), were tested over a white/black background, and divided in five groups (n=6) to be tested over five substrates (polished gold alloy, white zirconia and composite, dentine and enamel A1 colour). The L*, C*, h*, a*, b* and Δ E values, were recorded in two thicknesses (1.2 and 2.4 mm). Translucency parameter (TP), contrast ratio (CR) and opalescence parameter (OP) were calculated. Data was analysed with non­parametric tests: Mann Whitney between ceramic materials for thickness, Wilcoxon for thicknesses in substrates and ceramic material and Kruskal­Wallis with Bonferroni corrections tests (p<0,01) for substrates. Results: For 2.4 mm, the Δ E values were always higher independently of ceramic material or substrates. Vita Suprinity registered lower values than Celtra Duo. Zirconia substrate registered the lower values. For 1.2 mm, dentine registered the lower values. Gold alloy and composite substrates registered the lower Δ E values for 1.2 mm Celtra Duo and 2.4 mm Vita Suprinity specimens. CT and OP higher values and TP lower values were registered for 2.4 mm Vita Suprinity. It was impossible to calculate for Celtra Duo specimens. Conclusions: Background, substrate and thickness had significant influence in light behaviour and final color of ZLS glass ceramics. Substrates Gold alloy and dentine exhibited clinical acceptable Δ E values for 1.2 mm Celtra Duo specimens. (AU)


Objetivo: Avaliar a influência do fundo, do substrato e da espessura no comportamento da luz e na cor de duas cerâmicas ZLS. Material e métodos: Discos de cerâmica (12 x 1.2 mm) de cor A1 HT, de Celtra Duo e Suprinity (n=30), foram testados sobre fundo branco/preto e cinco substratos (liga Ag-Au-Pt polida; zircónia branca; compósito, dentina e esmalte de cor A1). Os valores L*, C*, h*, a*, b* e Δ E foram registados em duas espessuras (1.2 mm e 2.4 mm). O parâmetro de translucidez (TP), o parâmetro de opalescência (OP) e o índice de contraste (CR) foram determinados. Foram realizados testes não paramétricos: Mann Whitney entre cerâmicas por espessura, Wilcoxon entre categoria de espessura por substrato e cerâmica; Kruskal­Wallis com correção de Bonferroni para substratos (p <0,01). Resultados: Para 2,4 mm, o Δ E foi sempre superior independentemente do material ou substrato. Os valores de Suprinity foram inferiores aos de Celtra Duo. O substrato zirconia obteve o Δ E mais baixo. Para 1,2 mm, a dentina obteve o Δ E mais baixo. A liga dourada e o compósito obtiveram Δ E mais baixo para Celtra Duo 1,2 mm e Suprinity 2,4 mm. Para Suprinity, CT e OP foram maiores para 2,4 mm e menores para TP. Não foi possível calcular para Celtra Duo. Conclusão: O fundo, substrato e espessura tiveram influência significativa no comportamento da luz e cor das restaurações de cerâmica ZLS. Apenas os substratos metal e dentina apresentaram valores clinicamente aceitáveis, para Celtra Duo na espessura de 1.2 mm.(AU)


Subject(s)
Color , Composite Resins , Dental Enamel , Dental Materials , Dentin
SELECTION OF CITATIONS
SEARCH DETAIL